0
  • DE
  • EN
  • FR
  • Base de données et galerie internationale d'ouvrages d'art et du génie civil

Publicité

Two-dimensional transient thermal analysis of drilled-pile wall exposed to extreme temperatures and discussion on frost mitigation methods

 Two-dimensional transient thermal analysis of drilled-pile wall exposed to extreme temperatures and discussion on frost mitigation methods
Auteur(s): , , ,
Présenté pendant IABSE Symposium: Construction’s Role for a World in Emergency, Manchester, United Kingdom, 10-14 April 2024, publié dans , pp. 573-580
DOI: 10.2749/manchester.2024.0573
Prix: € 25,00 incl. TVA pour document PDF  
AJOUTER AU PANIER
Télécharger l'aperçu (fichier PDF) 0.22 MB

This paper analyzes earth-retaining walls made of drilled or bored large-diameter steel piles filled with concrete subject to Nordic temperature loads, especially focusing on Finnish temperature co...
Lire plus

Détails bibliographiques

Auteur(s): (Ramboll Finland Oy, Espoo, Finland)
(Ramboll Finland Oy, Espoo, Finland)
(Ramboll Finland Oy, Tampere, Finland)
(Ramboll Finland Oy, Tampere, Finland)
Médium: papier de conférence
Langue(s): anglais
Conférence: IABSE Symposium: Construction’s Role for a World in Emergency, Manchester, United Kingdom, 10-14 April 2024
Publié dans:
Page(s): 573-580 Nombre total de pages (du PDF): 8
Page(s): 573-580
Nombre total de pages (du PDF): 8
DOI: 10.2749/manchester.2024.0573
Abstrait:

This paper analyzes earth-retaining walls made of drilled or bored large-diameter steel piles filled with concrete subject to Nordic temperature loads, especially focusing on Finnish temperature conditions and their effects and mitigation methods. Two-dimensional numerical analysis is carried out with Finite Element Method (FEM) software Comsol Multiphysics 6.1. The result’s order of magnitude is validated by a literature review and by a one-dimensional analytical model. The paper aims to understand the frost depths with and without thermal insulation and to find their optimal locations. Results show that the thermal insulation layers might not give the intended benefits if the thermal bridges are not mitigated carefully. Moreover, it is evident from analysis that the horizontal part of the insulation covering the top of the ground plays an important role in decreasing the frost depth. The important findings will help designers reduce material waste, save public money in big infrastructure projects, and preserve the environment.

Mots-clé:
mur de retenue