0
  • DE
  • EN
  • FR
  • Base de données et galerie internationale d'ouvrages d'art et du génie civil

Publicité

Spiral Post-tensioning System for Concrete Members

 Spiral Post-tensioning System for Concrete Members
Auteur(s): , ,
Présenté pendant IABSE Symposium: Sustainable Infrastructure - Environment Friendly, Safe and Resource Efficient, Bangkok, Thailand, 9-11 September 2009, publié dans , pp. 72-79
DOI: 10.2749/222137809796078621
Prix: € 25,00 incl. TVA pour document PDF  
AJOUTER AU PANIER
Télécharger l'aperçu (fichier PDF) 0.03 MB

Four thick-walled 1 008 mm (39.7 in.) long cylindrical specimens with an inside diameter of 304.8 mm (12 in.), a wall thickness of 76.2 mm (3 in.), and a monolithically cast 250 mm (9.8 in.) long f...
Lire plus

Détails bibliographiques

Auteur(s):


Médium: papier de conférence
Langue(s): anglais
Conférence: IABSE Symposium: Sustainable Infrastructure - Environment Friendly, Safe and Resource Efficient, Bangkok, Thailand, 9-11 September 2009
Publié dans:
Page(s): 72-79 Nombre total de pages (du PDF): 8
Page(s): 72-79
Nombre total de pages (du PDF): 8
Année: 2009
DOI: 10.2749/222137809796078621
Abstrait:

Four thick-walled 1 008 mm (39.7 in.) long cylindrical specimens with an inside diameter of 304.8 mm (12 in.), a wall thickness of 76.2 mm (3 in.), and a monolithically cast 250 mm (9.8 in.) long flange at either end were fabricated. For three of the specimens, a spiral post-tensioning system consisting of four clockwise and four counterclockwise outside wrapping strands was used. The fourth specimen had eight post-tensioned straight strands. Specimens were fabricated using high performance, self-consolidating concrete and 12.5 mm (0.5 in.) DYWIDAG® Monostrand® post- tensioning tendons. Each specimen was supported at the ends and point loaded at mid-span. Spiral specimens were post-tensioned to 25%, 50%, and 75% of strand capacity while the specimen with straight strands was post-tensioned to 50% capacity. The spiral post-tensioning system increased ultimate capacity by 45% when compared with the specimen having longitudinally aligned strands.

Mots-clé:
béton tuyaux