0
  • DE
  • EN
  • FR
  • Base de données et galerie internationale d'ouvrages d'art et du génie civil

Publicité

Seismic Vulnerability Study of Precast Segmental Piers with Bonded Tendons

 Seismic Vulnerability Study of Precast Segmental Piers with Bonded Tendons
Auteur(s): , , , ,
Présenté pendant IABSE Congress: Bridges and Structures: Connection, Integration and Harmonisation, Nanjing, People's Republic of China, 21-23 September 2022, publié dans , pp. 1799-1807
DOI: 10.2749/nanjing.2022.1799
Prix: € 25,00 incl. TVA pour document PDF  
AJOUTER AU PANIER
Télécharger l'aperçu (fichier PDF) 0.15 MB

The widely applications of precast segmental bridge piers in high-seismicity areas are hindered for their insufficient capacities of energy dissipation. In this study, precast segmental piers’ seis...
Lire plus

Détails bibliographiques

Auteur(s): (School of Civil Engineering, Southeast University, Nanjing, China)
(School of Civil Engineering, Southeast University, Nanjing, China)
(School of Civil Engineering, Southeast University, Nanjing, China)
(School of Civil Engineering, Southeast University, Nanjing, China)
(School of Architecture Engineering, Nanjing Institute of Technology, Nanjing, China)
Médium: papier de conférence
Langue(s): anglais
Conférence: IABSE Congress: Bridges and Structures: Connection, Integration and Harmonisation, Nanjing, People's Republic of China, 21-23 September 2022
Publié dans:
Page(s): 1799-1807 Nombre total de pages (du PDF): 9
Page(s): 1799-1807
Nombre total de pages (du PDF): 9
DOI: 10.2749/nanjing.2022.1799
Abstrait:

The widely applications of precast segmental bridge piers in high-seismicity areas are hindered for their insufficient capacities of energy dissipation. In this study, precast segmental piers’ seismic behaviours were investigated, focusing on the connection of “grouted sleeves/bonded tendons”. Four piers were cyclically loaded, of one cast-in-place pier, one precast segmental pier, and two prestressed precast segmental piers. Experimental results showed that bonded tendons apparently enhanced the pier’s lateral strength, ductility, energy dissipation capacity and reducing residual drift. Of particular, bonded tendons prevented the shear-induced slip between the shaft and footing segments. Furthermore, seismic vulnerability assessments of the bridge piers are obtained in terms of fragility curves. Residual drift is adopted to define the limit states. It is suggested that bonded tendons could significantly ameliorate the fragility curves of precast segmental piers.

Mots-clé:
pile
Copyright: © 2022 International Association for Bridge and Structural Engineering (IABSE)
License: