Monitoring shear-induced degradation of reinforced and pre- tensioned concrete members

 Monitoring shear-induced degradation of reinforced and pre- tensioned concrete members
Auteur(s): , , ORCID
Présenté pendant IABSE Conference: Structural Engineering: Providing Solutions to Global Challenges, Geneva, Switzerland, September 2015, publié dans , pp. 1148-1157
DOI: 10.2749/222137815818358394
Prix: € 25,00 incl. TVA pour document PDF  
AJOUTER AU PANIER
Télécharger l'aperçu (fichier PDF) 0.09 MB

In the frame of a research project funded by the Austrian Research Foundation (FFG) 2 series of 4 pre-tensioned and non prestressed beams with rectangular and T-shaped cross-sections have been prod...
Lire plus

Détails bibliographiques

Auteur(s): (Carinthia University of Applied Sciences, Spittal an der Drau, Austria)
(Carinthia University of Applied Sciences, Spittal an der Drau, Austria)
ORCID (University of Natural Resources and Life Sciences, Vienna, Austria)
Médium: papier de conférence
Langue(s): anglais
Conférence: IABSE Conference: Structural Engineering: Providing Solutions to Global Challenges, Geneva, Switzerland, September 2015
Publié dans:
Page(s): 1148-1157 Nombre total de pages (du PDF): 10
Page(s): 1148-1157
Nombre total de pages (du PDF): 10
Année: 2015
DOI: 10.2749/222137815818358394
Abstrait:

In the frame of a research project funded by the Austrian Research Foundation (FFG) 2 series of 4 pre-tensioned and non prestressed beams with rectangular and T-shaped cross-sections have been produced in order to investigate the behaviour under shear loading and also the effect of the prestress on load bearing capacity and on ductility. In order to investigate the interaction between shear force, bending moment und normal force the pre-tensioning was varied between 100% and 50%. Special focus was laid on the crack development and SLS criteria as well as the ductility after reaching ultimate load level. During the first test series different conventional measuring methods were used to monitor the external and internal deformations caused by shear loading, in order to evaluate the sensitivity and correlation of the different measurements. As a result of the first test series, the monitoring layout and the performed numerical analyses were optimized and modern measurement methods in terms of DIC step wisely integrated into the further test series. Finally, the suitability of the different applied measuring techniques for recording shear behaviour and the potential to optimize the monitoring of shear degradation was evaluated.